Product description:
1. Click on the test, the result shows the frequency, power, and frequency offset value of the current Bluetooth device, the approximate time is 1.5S
2. Click calibrate to automatically calibrate the current frequency, write the value of the calibration number to the Bluetooth device, and display the frequency, power, and frequency offset values of the Bluetooth device after calibration. The approximate time is 5s.
3. The frequency range is selected according to the actual product standards, and the strict requirements are ±10kHz, generally ±20kHz.
4. The power range setting mainly filters equipment with low power
5. It can be tested by antenna induction. The input sensitivity of the SA4400 simple spectrum is about-70dBm, the maximum effective power of the input is 0dBm, and the maximum power of the port is 0dBm. If the direct connection power is too large, please add an attenuator.
==================================
v2.0 update instructions
1. Support qcc308x/qcc518x series
2. Optimize situations that may get stuck
==================================
v1.9 update instructions
1. Support qcc307x/qcc517x series
==============================
v1.0.7 version update
Delete undetected dongle prompt
Support qcc305x/qcc515x series
Increase test speed
==============================
v1.0.6 version update
1. Fix the bug that closing the window may get stuck
==============================
v1.0.5 version update
1. The optimized frequency can be tested in a range of ±250k (center frequency 2441MHz)
==============================
v1.0.4 version update
1. Optimize port initialization, Bluetooth restart problem
2. The encryption method is changed from the registration code to the USB dongle
==============================
2020.09.21 update
1. Latest version v1.0.3
2. Fix the bug that the frequency deviation is too large and the calibration fails
==============================
2020.09.17 update
1. Latest version v1.0.2
2. Fix the problem that qcc514x is prone to failure
3. Optimize frequency calibration accuracy
==============================
20200908 update
1. Latest version v1.0.1
2. Increase tool stability
3. Improve the calibration accuracy of qcc304x/qcc514x
==============================
This belongs to version v1.0. Support qcc302x, qcc303x, qcc304x, qcc512x, qcc514x series chips.The most economical frequency calibration scheme on the market can also test power (fixed frequency power).Compared with the frequency meter, it is more convenient and can be tested for antenna coupling.